Welcome to OPAL

Motor systems have a significant potential of energy savings. This application has been developped to find the most cost-effective actions to reduce energy consumption of motor-driven pump systems.


NEW: includes motors compliant to the new efficiency standard IEC 60034-30:2008

How to increase efficiency?

To increase the energy efficiency of an electric motor system the following steps are generally required:

  • acquire the component and the load profile data of the drive system.
  • examine different saving actions and compare the results.

Click here to learn more about OPAL.


Feedback

Your feedback is appreciated. Feel free to contact the developers at opal(at)semafor.ch

Disclaimer

This product is designed as a decision aid for energy saving actions. No warranties, either expressed or implied, with respect to this software or with respect to its fitness for any particular purpose is claimed by Semafor or the author. The software is provided solely on an "as is" basis. The entire risk as to its quality and performance is with the user of this software.

Resources

The following is a list of useful resources that provide additional information about energy efficiency:

Click to Change Theme
Search Filter
ModelManufacturerCatalogOutput [kW]Encl.Eff.LevelEff. FL [%]Voltage [V]Speed [1/min]
Cast Iron - Top Premium WEG 2005 Data 7.5 IP55 90.3 400 1500
Cast Iron_STDEFF Teco 7.5 IP54 89.6 400 1500
EMM3774-65 Baldor UK General Purpose 7.5 IP55 89.6 380 1500
EMM3774-58 Baldor UK General Purpose 7.5 IP55 89.6 400 1500
KTE2 132 M 4 Kuenle KTE2W-0507 7.5 IP55 89.5 400 1500
DVE132M4 SEW Eurodrive General 7.5 IP54 89.4 400 1500
CI - Prem Eff WEG 2005 Data 7.5 IP55 89.0 400 1500
Advantage+ V series Teco TBC 7.5 IP55 88.9 400 1500
<Default EFF1 motor> <default> 7.5 88.9 400 1500
DM1-HE 132M4 Dutchi Motors B.V. 11134750HE 7.5 IP55 88.9 400 1500
Motor Load
Load [%]Duration
72.01
Motor 1 Nameplate
<Default EFF3 motor>
7.5 1450 83.7
Motor 2 Nameplate
<Default EFF1 motor>
7.5 1455 88.9
Pumping System Load
Flow/Nom. Flow [%]Duration
801
Pump Nameplate
Motor Nameplate
<Default EFF3 motor>
7.5 1450 83.7